Our Vision A Sustainable Future for All

More Information

(+86) 23 6779 2685

Deye SUN-70K-110K-G03 Solar Inverter

Deye SUN-70K-110K-G03 Solar Inverter grid-connected inverter is suited for medium and large-scale commercial rooftops and ground-mounted solar PV system in which reliability and stability are important. the full series inverter has 30% DC input oversizing ratio and 10% AC output overloading ratio, offering a faster return on investment.

Features:

1.Max. 6 MPP trackers, Max. efficiency up to 98.8%
2.Zero export application, VSG application
3.String intelligent monitoring (optional)
4.Wide output voltage range
5.Type II DC/AC SPD
6.Anti-PID function (Optional)
7.AFCI function (Optional)

ModelSUN-70K-G03SUN-75K-G03SUN-80K-G03SUN-90K-G03SUN-100K-G03SUN-110K-G03
PV String Input Date 
Max. PV Input Power(kW)9197.5104135150150
Max. PV Input Voltage(V)1000
Start-up Voltage(V)250
MPPT voltage range(V)200-850
Rated PV Input voltage(V)600
Max. Input Short Circuit Current (A)60+60+60+6060+60+60+60+60+60
Max. Operating PV Input Current(A)40+40+40+4040+40+40+40+40+40
No. of MPP Trackers/No. of Strings per MPP Tracker4/4+4+4+46/4+4+4+4+4+4
AC Input/Output Side 
Rated AC Output Active Power(kW)70758090100110
Max. AC Output Apparent Power(kVA)7782.58899110121
Rated AC output current (A)106.1/101.5113.6/108.7121.2/115.9136.4/130.4151.5/144.9166.7/159.4
Max. AC Output Current(A)116.7/111.6125/119.6133.3/127.5150/143.5166.7/159.4183.3/175.4
Rated output voltage/range (V)220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form3L+N+PE
Rated Output Grid Frequency/range(Hz)50Hz/45Hz-55Hz    60Hz/55Hz-65Hz
Power Factor Adjustment Range0.8 leading to 0.8lagging
Total Current Harmonic Distortion THDi<3%
DC Injection Current<0.5%ln
Efficiency 
Max. Efficiency98.70%98.80%
Euro Efficiency98.10%98.20%
MPPT Efficiency>99%
Equipment Protection 
DC Polarity Reverse Connection Protectionyes
AC Output Overcurrent Protectionyes
AC Output Overvoltage Protectionyes
AC Output Short Circuit Protectionyes
Thermal Protectionyes
DC Terminal Insulation Impedance Monitoringyes
DC Component Monitoringyes
Ground Fault Current Monitoringyes
Power Network Monitoringyes
Island Protection Monitoringyes
Earth Fault Detectionyes
DC Input Switchyes
Overvoltage Load Drop Protectionyes
Residual Current (RCD) Detectionyes
Surge Protection LevelTYPE II(DC),TYPE II(AC)
Interface 
Communication InterfaceRS485/RS232 /WiFi/LAN
General Data 
Operating Temperature Range (°C)-25 to +65℃, >45℃ Derating
Permissible Ambient Humidity0~100%
Permissible Altitude (m)4000m
Noise (dB)≤ 55
Ingress Protection(IP) RatingIP 65
Inverter TopologyNon-Isolated
Over Voltage CategoryOVC II(DC),OVC III(AC)
Cabinet Size (WxHxD mm)826mm*516mm*312.7mm(Excluding connectors and brackets)
Weight [kg]81
Warranty [year]5 years
Type Of CoolingIntelligent air cooling
Grid RegulationIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety EMC/StandardIEC/EN 62109-1,IEC/EN 62109-2,IEC/EN 61000-6-1,IEC/EN 61000-6-2,IEC/EN 61000-6-3,IEC/EN 61000-6-4
en_USEnglish