Our Vision A Sustainable Future for All

More Information

(+86) 23 6779 2685

DEYE SUN-4K-15K-G06P3-EU-AM2 Solar Inverter

This series inverter is specially designed for three-phase PV systems, covering a wide power range of 4kW, 5kW, 6kW, 7kW, 8kW, 10kW, 12kW,15kW. With compactness design, it is easy to install and operate. It supports wide AC output voltage to ensure longer working hour.

Features:

1.2 MPP tracker, Max. efficiency up to 98.5%
2.Zero export application, VSG application
3.String intelligent monitoring (optional)
4.Wide output voltage range
5.Anti-PID function (Optional)

ModelSUN-4K-G06P3-EU-AM2SUN-5K-G06P3-EU-AM2SUN-6K-G06P3-EU-AM2SUN-7K-G06P3-EU-AM2SUN-8K-G06P3-EU-AM2SUN-10K-G06P3-EU-AM2SUN-12K-G06P3-EU-AM2SUN-15K-G06P3-EU-AM2
PV String Input Date 
Max. PV Input Power(kW)5.26.57.89.110.41315.619.5
Max. PV Input Voltage(V)1100
Start-up Voltage(V)140
MPPT voltage range(V)120-1000
Rated PV Input voltage(V)600
Max. Input Short Circuit Current (A)19.5+19.519.5+39
Max. Operating PV Input Current(A)13+1313+26
No. of MPP Trackers/No. of Strings per MPP Tracker2/1+12/1+2
AC Input/Output Side 
Rated AC Output Active Power(kW)45678101215
Max. AC Output Apparent Power(kVA)4.45.56.67.78.81113.216.5
Rated AC output current (A)6.1/5.87.6/7.39.1/8.710.7/10.212.2/11.615.2/14.518.2/17.422.8/21.8
Max. AC Output Current(A)6.7/6.48.4/810/9.611.7/11.213.4/12.816.7/1620/19.225/24
Rated output voltage/range (V)220/380V, 230/400V 0.85Un-1.1Un
Grid Connection Form3L/N/PE
Rated Output Grid Frequency/range(Hz)50/45-55, 60/55-65
Power Factor Adjustment Range0.8 leading to 0.8lagging
Total Current Harmonic Distortion THDi<3%
DC Injection Current<0.5%ln
Efficiency 
Max. Efficiency98.10%98.20%98.30%98.50%
Euro Efficiency97.50%97.60%97.80%98.00%
MPPT Efficiency>99%
Equipment Protection 
DC Polarity Reverse Connection Protectionyes
AC Output Overcurrent Protectionyes
AC Output Overvoltage Protectionyes
AC Output Short Circuit Protectionyes
Thermal Protectionyes
DC Terminal Insulation Impedance Monitoringyes
DC Component Monitoringyes
Ground Fault Current Monitoringyes
Power Network Monitoringyes
Island Protection Monitoringyes
Earth Fault Detectionyes
DC Input Switchyes
Overvoltage Load Drop Protectionyes
Residual Current (RCD) Detectionyes
Surge Protection LevelTYPE II(DC),TYPE II(AC)
Interface 
Communication InterfaceRS485/RS232 /WiFi/LAN
General Data 
Operating Temperature Range (°C)-25 to +60℃, >45℃ Derating
Permissible Ambient Humidity0~100%
Permissible Altitude (m)4000m
Noise (dB)<45 dB(A)
Ingress Protection(IP) RatingIP 65
Inverter TopologyNon-Isolated
Over Voltage CategoryOVC II(DC),OVC III(AC)
Cabinet Size (WxHxD mm)283mm*463mm*178mm(Excluding connectors and brackets)
Weight [kg]11
Warranty [year]5 years
Type Of Coolingnatural cooling
Grid RegulationIEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
en_USEnglish